Zircon Stud Sensor SL AC User Manual

WORKING WITH DIFFERENT MATERIALS  
S t u d S e n s o r P r o S L -A C S t u d F in d e r  
StudSensor Pro SL-AC is for use on dry, interior walls only. Although StudSensor Pro  
SL-AC can scan through up to  
w it h A C W ir e W a r n in g  
S p o t L it e  
a n d  
112 in. (38 mm) of common construction materials in DeepScan mode, three pri-  
mary factors can affect sensing depth: thickness, density, and moisture content.  
®
P o in t in g S y s t e m  
StudSensor Pro SL-AC can scan effectively through most sheet materials, including:  
Bare wood flooring (in DeepScan mode)  
Linoleum on wood base  
Gypsum drywall over plywood sheathing  
Wallpapered walls (if dry)  
Textured ceilings if uniform thickness (Place a thin piece of cardboard on ceiling  
and scan through it to avoid damage  
to texturing.)  
The Zircon StudSensorPro SL-AC  
detects wood and metal studs  
and joists in walls, floors, and  
ceilings. It features two scanning  
modes, recessed LEDs, a durable  
high-impact case, and the  
SpotLite® Pointing System  
Stud Edge Groove  
StudSensor Pro SL-AC is not designed to scan materials with inconsistent density  
such as:  
Ceramic floor tile  
Carpeting and padding  
Wallpaper with metallic fibers  
Freshly painted walls that are still damp (must dry at least  
a week)  
patented SpotLite® Pointing System.  
It also has WireWarning™  
TruCal®  
LED  
AC WireWarning™  
to continuously detect hot  
AC voltage in both modes.  
STUD SCAN  
DEEPSCAN®  
Stud DeepScan®  
Mode LED  
StudScan  
Mode LED  
Lath and plaster walls  
Foil covered insulation board  
Mode Switch  
On/Off Button  
FCC Part 15 Class B Registration Warning  
INSTALLING THE BATTERY  
This equipment has been tested and found to comply with the limits for a Class B digital device, pur-  
suant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against  
harmful interference when the  
equipment is operated in a residential installation. This equipment generates, uses, and can radiate  
radio frequency energy and, if not installed and used in accordance with  
the instructions, may cause harmful interference to radio communications. However, there is no guar-  
antee that  
Squeeze sides of  
clip to help  
1
release clip end.  
interference will not occur in a particular installation. If  
When the top green  
LED is lit, a steady  
tone sounds, and the  
SpotLite® shines, you  
have located the edge of  
the stud. Mark this spot.  
this equipment does cause harmful interference to radio or television reception, which can be deter-  
mined by turning the equipment off and on, the user is encouraged to try to correct the interference  
by one or more of the following measures:  
9
Slide 9-V battery  
2
into compartment,  
terminal side first,  
matching (+) and (–)  
terminals from battery to case.  
(1) Reorient or relocate the receiving antenna.  
(2) Increase the separation between the equipment and receiver.  
(3) Connect the equipment into an outlet on a circuit,  
different from that which the receiver is connected  
(if applicable).  
(4) Consult the dealer or an experienced radio/TV  
technician for help.  
Replace the clip.  
3
Battery will last  
approximately two years  
under normal conditions.  
Continue scanning  
10  
beyond marked  
spot until green LED goes  
out. Slide unit in reverse  
direction to locate other  
edge of stud.  
CALIBRATION AND SCANNING IN  
STUD SCAN OR DEEPSCAN® MODES  
H E L P F U L H IN T S  
Note: Unit calibrates on each use.  
Situation  
Probable Causes  
Solutions  
3
Lights start flashing and Scan began on dense part of  
Turn unit off, move over a few inches, press On/Off button,  
and start again.  
Use Stud Scan Mode for depths to about  
(19 mm) and DeepScan for depths up to  
112 in. (38 mm) or double layers.  
in.  
4
unit starts beeping.  
wall or over a stud.  
Mark this second  
11  
is centered between the  
Unit not flat against wall.  
Unit tilted or lifted during scan.  
On rough surfaces, place piece of paper on wall, scanning  
through it to help slide unit more smoothly.  
spot. Middle of stud  
(All these factors affect proper Keep hand at least 6 in.(152 mm) from StudSensor  
calibration.)  
Pro SL-AC while you calibrate and scan. Hold unit with  
thumb and index finger no higher than handgrips. Be  
careful not to move your fingers after calibration.  
Always hold unit parallel to and move perpendicular to  
object you’re trying to locate.  
two marks.  
Note: Keep unit flat against wall. Do not lift or tilt  
unit during calibration or scanning.  
Slide the Mode Selector  
switch to the desired  
4
Center green LED doesn’t Wall is particularly thick or  
Interpret red LED closest to center as stud edge.  
Switch to DeepScan to locate the stud.  
light in Stud Scan mode.  
dense.  
scanning mode. The mode can  
be selected with the unit on  
or off.  
CONTINUOUS AC VOLTAGE  
DETECTION (WireWarning™  
)
The green TruCal LED  
lights but, when scan-  
ning, unit doesn't do  
anything else.  
Unit may not be flat against  
the wall.  
If it is in the DeepScan mode  
(the DeepScan LED is lit), you  
may have calibrated over a stud.  
Hold unit so two Velcrostrips on the back make  
contact with wall.  
Recalibrate unit in a different place and rescan area.  
The StudSensor Pro  
12  
SL-AC detects from  
With StudSensor Pro SL-AC  
5
90 to 250 V at 50 to 60 Hz  
AC in a hot electrical wire.  
The voltage detection  
feature works continuously  
in both Stud Scan and  
DeepScan modes. When  
sensing voltage, the small  
AC light comes on.  
turned off, position the unit  
flat against the wall.  
All three red LEDs and  
green LED light at the  
same time and unit  
beeps continuously.  
Scanning surface is too dense  
or too wet for unit to operate.  
If you are using unit on a recently taped, painted, or  
wallpapered wall, allow time to dry and try again.  
Working in DeepScan  
mode and can’t detect  
studs.  
You may have calibrated over  
a stud. (The error condition is  
disabled in DeepScan mode  
because it is twice as sensitive  
as Stud Scan.)  
Move StudSensor Pro SL-AC over a few inches  
and recalibrate.  
Without moving unit, squeeze  
6
and hold On/Off button.  
TruCal® LED should be lit.  
Caution: The StudSensor Pro SL-AC will not  
detect hot wires inside metal pipe or conduit,  
behind metallic wall covering, or behind some  
plywood or other dense materials. Use extra  
caution in these situations. Always turn the  
power off when nailing, cutting, or drilling  
near electrical wires.  
You may be holding the unit  
like a TV remote, aiming it at  
the wall.  
Hold unit so two Velcrostrips on the back make  
contact with wall.  
Detects other objects  
besides studs.  
Electrical wiring and metal or  
plastic pipes may be near or  
touching back surface of wall.  
Remember that studs or joists are normally spaced 16 in.  
(406 mm) or 24 in. (610 mm) apart and are 112 in.  
(38 mm) wide.  
Always turn off power when cutting, nailing, or drilling  
near electrical wires.  
Continue to hold  
in the On/Off  
7
You suspect electrical  
wires, but do not  
detect any.  
Wires may be shielded behind  
metallic wall coverings,  
plywood shearwall or other  
dense material, or in conduit;  
StudSensor Pro SL-AC may not  
be able to find them.  
See above solution.  
button then slowly slide  
unit horizontally across  
the wall, right or left.  
OPERATING CAUTIONS  
Use extra caution if the area has plywood, thick wood  
backing behind drywall, or thicker-than-normal walls.  
If a switch controls an outlet, make sure it is ON for  
detection, but turned off when working near electrical wires.  
Depending on the proximity of electrical wiring  
13  
or pipes to the wall surface, the scanner may  
The wires may not be hot.  
Wires may be too deep to sense.  
detect them in the same manner as studs. Caution  
should always be used when nailing, cutting, or  
drilling in walls, floors, and ceilings that may contain  
these items.  
Area of voltage detection Static charge may develop on  
To narrow detection, turn unit off and on again at the edge  
of where wire was detected and scan again.  
As you begin to approach a stud, the red LEDs  
will light successively, from bottom to top.  
is too large.  
drywall, spreading voltage  
detection as much as 12 in.  
(305 mm) from each side of  
an actual electrical wire.  
8
To avoid surprises, remember that studs or joists are  
normally spaced 16 in. (406 mm) or 24 in. (610 mm)  
apart and are 112 in. (38 mm) in width. Anything  
closer together or a different width may not be a  
stud, joist, or firebreak. Always turn off the power  
when wDoorwkinnglonaedarferolemctriWcalwwwir.eSs.omanuals.com. All Manuals Search And Download.  

Wells Waffle Iron WB 1 User Manual
Wharfedale Portable Speaker Link 800 User Manual
Whirlpool Hot Tub PORTABLESPA User Manual
White Rodgers Thermostat 1F87 51 User Manual
Wolfgang Puck Rice Cooker BDRCRS007 User Manual
Yamaha Music Mixer IM8 24 User Manual
Zanussi Freezer VF45 User Manual
Zanussi Range ZGG642C User Manual
Zanussi Ventilation Hood 642011 User Manual
Zanussi Washer Dryer ZJD12191 User Manual